返回首頁
 
[ 攝影機 | SONY | XCD-U100 / XCD-U100CR ]

SONY 機械視覺/工廠自動化 | XCD-U100 / XCD-U100CR

搭配鏡頭:Computar、Fujinon、KOWA、Moritex、Myutron、Navitar、Optem、Pentax、Tamron、Kenko等。
應用領域:機械視覺用攝影機、工廠自動化FA用攝影機、光學自動檢測AOI用攝影機、 顯微鏡用攝影機、
                  工業用攝影機等。

FA/光學自動檢測AOI 專用攝影機系列

1/1.8-type progressive scan CCD攝影機
Model:Sony XCD-U100(黑白) / XCD-U100CR(彩色)


XCL-U100 / XCL-U100CR


Features:

1/1.8 type Progressive Scan CCD .
IEEE 1394b Digital Interface
Up to 15 fps at UXGA Resolution
Multi-Connection Capability
Multi-Trap Function
Broadcast Delivery
Various Frame Rates for High Speed Capturing
Supports IIDC Protocol
Built-in Real-time 3X3 Image Pre-Processing Filter
High Shock and Vibration Resistance
Compact and Lightweight
   
Bulk Trigger Mode  
Slow Shutter Speed High Shutter Speed Composite Image with Wide Dynamic Range
   

Dimensions:
 
 
 

Specifications:

 
XCD-U100
XCD-U100CR
Image device 1/1.8-type progressive scan IT CCD
Standard picture size (H x V) 1600 x 1200 (UXGA)
Cell size (H x V) 4.4 x 4.4 µm
Resolution depth Mono 8: 8 bits/pixe
Mono 16: 10 bits/pixe
Raw 8: 8 bits/pixel
Raw 16: 10 bits/pixel
Lens mount C mount
Digital interface IEEE1394b-2002 x2, bilingual (screw lock possible)
Transfer rate 800 / 400 / 200 / 100 Mb/s
Max. Frame rate (at full resolution) 15 fps
Gain control Manual 0 to 24 dB,Auto gain Manual 0 to 18 dB,Auto gain
Shutter speed 1/100,000 to 16s, Auto shutter
External trigger shutter Trigger start (Mode 0), Trigger start and exposure duration (Mode 1), Programmable trigger (via the IEEE1394 bus),
Trigger inhibit setting, Trigger/Strobe delay setting, Single/Bulk trigger mode
Image memory 16 MB
Memory channel 15 channels for parameter settings
Broadcast delivery Camera setting, Software trigger via IEEE1394 bus
Readout features Partial Scanning, Binning, LUT,
3x3 filter
Partial Scanning, LUT,
Bayer Pattern
Arrangement, AWB
Power requirements DC 8 to 30 V (via IEEE1394b 9-pin cable or 12-pin camera cable)
Power consumption 3.0 W (Typ.)
Dimensions (W x H x D) 1 3/4 x 1 5/16 x 2 3/8 inches (44 x 33 x 57.5 mm)
(not including protruding parts)
Weight 5 oz (140 g)
Operating temperature 23 to 113 ºF (-5 to 45 ºC)
Storage temperature -22 to 140 ºF (-30 to 60 ºC)
Operating humidity 20 to 80% (no condensation)
Storage humidity 20 to 95% (no condensation)
Vibration resistance 10 G (20 to 200 Hz)
Shock resistance 70 G
Supplied accessories Lens mount cap, Operating instructions
 
 
 
   
 